This product is designed and manufactured according to user requirements, and is suitable for high and low temperature impact tests of complete machines and parts of aviation, aerospace, military, ships, automobiles (including motorcycles), batteries, electronics and other products, and storage in high or low temperature environments And experiment. It is for users to make corresponding climate and environment accelerated tests on the whole machine (or components), electrical appliances, instruments, materials, coatings, plating, etc., so as to evaluate the test product or the test behavior of the test product.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
30 daysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0069Heat Shock Test For Batteries IEC60095-1
Products Introduction:
This product is designed and manufactured according to user requirements, and is suitable for high and low temperature impact tests of complete machines and parts of aviation, aerospace, military, ships, automobiles (including motorcycles), batteries, electronics and other products, and storage in high or low temperature environments And experiment. It is for users to make corresponding climate and environment accelerated tests on the whole machine (or components), electrical appliances, instruments, materials, coatings, plating, etc., so as to evaluate the test product or the test behavior of the test product.
Standard:
IEC60095-1
Main Parameters:
Model |
HCTE0069 |
Inner size |
500×500×600 (D×W×H mm) (150L) |
Temperature range of high temperature chamber |
+0℃ ~ +200℃ |
Low temperature chamber temperature range |
-70℃ ~ -0℃ |
Impact temperature range |
-70℃ ~ +200℃ |
Temperature fluctuation |
±0.1℃ (at constant state) |
Temperature uniformity |
≤2℃ (at constant state) |
Cooling time in low temperature zone |
from +20℃ to -40℃≤60min (when running alone) |
Heating time in high temperature zone |
from +20℃ to +125℃≤40min (when running alone) |
Conversion time |
≤15s, sample conversion |
The weight of the hanging chamber |
≥40Kg |
Temperature recovery time of impact test chamber |
≤5min (recovery conditions: high temperature 200℃, exposure for 15 minutes; low temperature -70℃, exposure for 1 minute; load 5Kg steel ingot or aluminum ingot I |
Redundancy system |
mechanical cascade refrigeration/air cooling |
Refrigeration working fluid |
R502/F13 |
Materials And Components:
The thermal shock test chamber is composed of the following parts:
Test chamber
Control system
Refrigeration system
Heating system
Pneumatic system
1. Test chamber
① The chamber adopts an upper and lower chamber structure, the upper part is a high temperature chamber, and the lower part is a low temperature chamber. The low temperature system is located at the back of the chamber, the pneumatic system is located on the left and right sides of the test chamber, and the electrical control cabinet is placed on the right side of the test chamber. Easy to operate.
② The inner wall of the test chamber is made of SUS304# stainless steel plate, and the outer shell of the chamber is made of high-quality cold-rolled steel plate, and the surface is electrostatically sprayed after pickling and phosphate treatment.
③ The heat preservation material of the high temperature chamber adopts superfine glass fiber, and the heat preservation material of the low temperature chamber adopts polyurethane foam, asbestos board and superfine glass fiber.
④ There is a condensate drain at the bottom of the low-temperature chamber
2. Control System
It is mainly composed of a central controller, power switch, and executive appliances. Unique defrosting control, after the test, the inside of the test chamber can be defrosted.
3. Refrigeration system
It is mainly composed of refrigeration compressor unit, condenser, condensing evaporator, oil separator, liquid reservoir (expansion pressure vessel), filter drier, hand valve, solenoid valve, etc.
4. Heating system
The heating system is divided into two parts: one part is located in the air duct system of the high temperature chamber, and the other part is located in the air duct system of the low temperature chamber. It is mainly composed of multiple sets of nickel-chromium alloy threaded electric heaters and PTFE sheathed wires. .
5. Pneumatic system
The pneumatic system is mainly composed of air cylinder, solenoid valve, filter, mechanical transmission device and other parts. Mainly control the up and down movement of the sample rack.