The equipment is suitable for electrical and electronic products, automobile, motorcycle parts, instruments, meters, lamps, home appliances and other products. In the process of storage, transportation and use, it is often affected by the sand and dust environment, especially automobiles and electrical appliances are more seriously affected by the sand and dust.It is suitable for the dustproof test of electrical products whose second characteristic number is "IP5X\IP6X".
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
30 daysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0060Dust Proof Test Equipment for Automobile Air Conditioning Compressor IPX5IPX6
Products Introduction:
The equipment is suitable for electrical and electronic products, automobile, motorcycle parts, instruments, meters, lamps, home appliances and other products. In the process of storage, transportation and use, it is often affected by the sand and dust environment, especially automobiles and electrical appliances are more seriously affected by the sand and dust.
Standard:
The basic structure, principle and performance of the equipment can meet the requirements of the protection level test of the shells of household appliances, automobiles and motorcycles in the standards of IEC60529, ISO20653, GB2423, DIN40050, and GB4208-2008. It is suitable for the dustproof test of electrical products whose second characteristic number is "IP5X\IP6X".
Feature:
1.The outer shell of the equipment is made of cold-rolled steel plate electrostatically sprayed, the inner tank is made of high-quality stainless steel plate, and the overall appearance is beautiful and generous.
2. There is a large-area observation window and a manual wiper device in the middle of the box door, which can easily see the test condition of the test piece during the test process.
3.The main controller of the equipment adopts intelligent digital display controller. The main controller of this equipment adopts intelligent digital display temperature controller.The operation method of humanized design is easy to learn and use, and the operation of instruments of different functional grades is compatible with each other.
4.The input adopts a digital correction system, with built-in non-linear correction tables for common thermocouples and thermal resistances, and the measurement is accurate and stable.
5.The heating adopts stainless steel fin heating tube, the dust blowing cycle and vibration cycle of the whole equipment can be adjusted, and the total test time is provided.
Technical Parameters:
Model |
HCTE0060 |
Experimental limitations |
This experimental equipment prohibits the following sample experiments 1.Experiments on flammable, explosive and volatile samples 2.Experiments on specimens of storage of corrosive substance 3.Experiments on specimens of storage of biological 4.Experiments on specimens of strong electromagnetic emission sources |
Volume |
500L |
Inner chamber size |
800mm*800mm*800 mm(length*width*height)(test 1 product) |
Evacuation connector |
Supplier provides fittings and plugs for connection to compressor pump down ports |
Special requirements |
Open a 50mm hole on the left side of the device, which is used as the input port of external electricity and gas. Seal with a plug when not in use. |
Performance indicators |
|
Use environmental conditions |
The ambient temperature is 5°C ~ 35°C, and the relative humidity is ≤85% (the value measured under the condition of no sample in the experimental box). |
Specification parameters |
Metal screen aperture: 75um, nominal spacing between lines is 75um (standard equipped with: talcum powder). Use dust: dry talc, Portland cement, etc. |
Sand direction |
from top to bottom |
Air velocity |
≤2.5m/S |
Dust dosage |
2㎏~3㎏/m³ |
Blowing time |
Range 0-999 hours (can be set) |
Vibration time |
Range 0-999 hours (can be set) |
Meet the condition |
The functions of the equipment meet the requirements of clause 13.4 in the standard GB/T 4208-2008 |
Chamber structure |
Inner box material:304# Stainless steel Outer box material: Using A3 steel plate to make surface electrostatic spray pattern The control and test box is an integral structure The inner bottom of the box is funnel-shaped. There is a vibrating dust concentration homogenizer. Dust collector |
Chamber door |
Single door Explosion-proof handle Oversized clear window on the door Window light Window wiper |
Control panel |
Temperature controller, Program control timer, Work light, power switch, Dust blowing switch, Dust shaking switch |
Mechanical room |
Dust blower, dust blowing outlet |
Test material rack |
304# stainless steel plate is punched and bent, and the material rack spacing and height are adjustable. |
Heating system |
The heating is controlled by the scale heat dissipation type heating tube P.I.D. |
Dust blowing method |
High-speed blower blows dust |
Dust shaking method |
Vibration motor shakes off the dust into dust collector |
Electrical control system |
|
Controller |
LCD touch screen Control temperature, dust blowing time, floating dust time, dust shaking time, standing time and cycle period. |
Input mode |
Human-machine interface, touch input |
Program capacity and control functions |
1. Available programs: 0~120 groups, each program consists of 1~99 segments of instructions. 2. During program execution, it has the function of skipping and holding, and can display the curve, data acquisition, date and time adjustment functions |
Operation mode |
Program method, Fixed value method |
Power-off memory |
Power-off recovery mode can be set as: hot start, cold start, stop |
Reservation function |
After the power is turned on, the start-up time can be set, and the experiment will be automatically started at the specified time. |
Temperature measurement |
PT100 type platinum resistance |
Curve recording function |
The set value, sampling value and sampling time of experimental parameters can be saved. |
Safety guards |
|
Test chamber |
Over temperature, fan motor overheat relay |
Power supply |
Leakage protection, overload and short circuit protection |
Installation site |
The gap between the two sides and rear wall of the device and other objects is not less than 800mm, and the distance from the front is not less than 1500mm |
Hot Tags :