The hot and cold impact test machine is to test whether the product has a bad impact due to the rapid changes of high and low temperature without moving the items to be tested. It is a necessary test equipment for metal, plastic, rubber, electrical and electronics, auto parts and other material industry.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
30 daysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0031Two-Box Cold and Hot Impact Tester IEC60068
Meet The Standards:
GJB 150.4-1986 Low-temperature test;
GJB 150.3-1986 High-temperature test;
GJB 150.5-1986 Temperature impact test;
GB / T 5170.2-1996 Temperature test equipment;
GB / T 2423.1-2001(IEC60068-2-1:1990) test A: Low temperature test method;
GB / T 2423.2-2001(IEC60068-2-2:1974)test B: High temperature test method;
GB / T 2423.22-2002(IEC60068-2-14:1984)test N: Temperature change test method test Na.
Two Boxes Of Hot And Cold Impact Technical Indicators:
Model |
HCTE0031-LC70 |
HCTE0031-LC100 |
HCTE0031-LC150 |
HCTE0031-LC252 |
Inner box size mm (W * H * D) |
500×350 ×400 |
500×400×500 |
600×500×500 |
700×600×600 |
Outline dimension mm (W * H * D) |
1500×1970×1900 |
1500×1740×2300 |
1620×2040×2450 |
1850×2300×2500 |
Temperature impact range |
A:-40~+150℃, B:-55~+150℃, C:-65~+150℃ |
|||
Cold storage temperature range in the low temperature area |
-10℃~-50℃; -10℃~-65℃; -10℃~-75℃ |
|||
Heat storage temperature range in the high temperature area |
+50℃~+180℃ |
|||
Impact reinstatement time |
About 5min |
|||
High and low temperature impact constant temperature time |
More than 30min |
|||
Nacelle conversion time |
≤8S |
|||
High temperature setting |
+60℃ ~ +150℃ |
|||
Low temperature setting |
-65℃ ~ -10℃ |
|||
Temperature fluctuation in the sample zone |
± 0.5℃ (at constant temperature) |
|||
Temperature accuracy range |
Set accuracy: ± 0.1℃, indicating accuracy: ± 0.1℃, resolution: ± 0.1℃ |
|||
Temperature deviation |
± 2℃ (no-load, at constant state) |
|||
Temperature sensor |
High-precision grade A PT100 temperature |
|||
Cryogen |
R404a,R23 |
|||
Internal box material |
SUS304 stainless steel plate |
|||
Outer box material |
A3 cold rolled steel plate electrostatic spray on both sides |
|||
Heat insulation material |
Hard polyurethane foam with insulation cotton |
|||
Round-robin mode |
Centrifugal fan |
|||
Heater |
Nickel-branded alloy electric heater |
|||
Refrigeration method |
Compound refrigeration (using Bizer semi-airtight compressor, Germany) |
|||
Controller |
The 7-inch color LCD touch control screen + PLC module |
|||
Cabas |
Built-in 2 shelfs |
|||
Running power |
About 9~30KW (auto-on heating and cooling based on PID operation) |
|||
Supply source |
380V ± 10%V; 50Hz; three-phase four-wire + grounding wire, protective grounding resistance is less than 4 Ω |
|||
Protection system |
Power supply phase deficiency and phase order error protection, leakage protection, heater overtemperature protection, heater short circuit and other overcurrent protection. |
Hot Tags :