Product introduction:
High-efficiency dehydration, degassing, and impurity removal: The ultra-high voltage transformer mutual inductor vacuum oil filling platform adopts efficient vacuum and three-dimensional evaporation technology, which can carry out dehydration, degassing, and impurity removal processing on the transformer oil in a short time, and improve the electrical and insulating properties of the oil.
Automatic control: This platform uses advanced automatic control system, which can achieve precise control of parameters such as the amount of oil filling, the oil filling level, and the vacuum degree, and improve the efficiency and accuracy of oil filling.
Safe and reliable: The ultra-high voltage transformer mutual inductor vacuum oil filling platform has multiple safety protection functions, such as oil overflow protection and overload protection, to ensure the safety of the operators and the stability of the equipment.
Strong adaptability: This platform can be customized according to different models and specifications of the ultra-high voltage transformer mutual inductor to adapt to different processing needs.
Energy saving and environmental protection: This platform adopts advanced energy-saving technology to reduce energy consumption and emissions, which meets environmental protection requirements. At the same time, the transformer oil is recycled to reduce waste and pollution.
High efficiency: The ultra-high voltage transformer mutual inductor vacuum oil filling platform can greatly improve the oil filling efficiency and dehydration efficiency, shorten the processing time, and improve production efficiency.
In short, the ultra-high voltage transformer mutual inductor vacuum oil filling platform is an efficient, safe, and reliable vacuum oil filling processing equipment, which is suitable for the processing of ultra-high voltage transformers and can meet the high-voltage requirements of the power system.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
30 daysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE-VTE-013Detection standards:
GB/T 19146-2011: 110 (66) kV ~ 220 kV oil-immersed transformers (reactors) technical parameters and requirements.
GB/T 1094.1-2013: Power transformers - Part 1: General.
GB/T 1094.2-2013: Power transformers - Part 2: Temperature rise of liquid-immersed transformers.
GB/T 1094.3-2003: Power transformers - Part 3: Insulation level, insulation tests and external insulation air gap of power transformers and their related equipment.
GB/T 15164-2013: Load guide for oil-immersed transformers.
GB/T 2900.10-2004: Electrical terminology - Transformers, voltage regulators and reactors.
GB/T 7252-2006: Guidelines for the analysis and determination of dissolved gases in transformer oil.
GB/T 7928-2014: Guide for selection of paper insulation materials for power transformer oil.
GB/T 16275-2015: Technical parameters and requirements of oil-immersed transformers.
IEC 60076-11:2014: Part 11 of power transformers, power supplies, reactors and similar products: Test of temperature rise of liquid-immersed transformers and other related equipment for switchgear.
IEC 60076-16:2013: Part 16 of power transformers, power supplies, reactors and similar products: Measurement of sound level of liquid-immersed transformers and other related equipment for switchgear.
IEC 60296:2003: Specification for insulating oil for power transformers.
IEEE Std C57.13.6-2002: Performance specification of insulating oil for oil-immersed bushings and insulators used for power transformers and reactors.
Detection items:
Performance testing: Test the various performance indicators of the testing platform, such as vacuum degree, oil filling speed, and amount of oil filling, to ensure that the platform performance meets the requirements.
Safety testing: Conduct testing on the safety performance of the platform, such as electrical safety and mechanical safety, to ensure that no safety accidents occur during the use of the platform.
Reliability testing: Test the reliability of the platform, such as the service life of the equipment and the replacement cycle of vulnerable parts, to ensure that the platform can operate stably during use.
Environment adaptability testing: Test the environment adaptability of the platform, such as the performance performance of the platform in different environments, and the anti-interference ability, to ensure that the platform can work normally in various environments.
Electromagnetic compatibility testing: Test the electromagnetic compatibility of the platform to ensure that the platform does not cause electromagnetic interference to the surrounding environment during use.
Material quality testing: Conduct quality testing on the materials used on the platform, such as the quality and corrosion resistance of the materials, to ensure that there are no failures due to material problems during the use of the platform.
Appearance and structure inspection: Inspect the appearance and structure of the platform, including the integrity of the platform, whether there is damage or corrosion, and the installation and connection of each component.
These testing items are important means to ensure the quality and performance of the ultra-high voltage transformer mutual inductor vacuum oil filling platform. Through regular testing and maintenance, potential problems can be discovered and resolved in a timely manner, and the operating efficiency and safety of the platform can be improved.
Test objects:
Mutual inductor body: Check the performance of the mutual inductor after oil filling, such as insulation resistance, dielectric loss, and electric field distribution.
Vacuum oil filling system: Test the sealing performance, flow control, pressure regulation and other parameters of the oil filling system to ensure that the system can inject the appropriate amount of oil as required.
Oil quality: Conduct quality testing on the injected oil, including the physical properties of the oil (such as viscosity, flash point, etc.) and chemical properties (such as acidity and alkalinity, water content, etc.) to ensure that the oil quality meets the requirements.
Platform control system: Test the stability and accuracy of the control system, including the performance testing of components such as sensors, control valves, and actuators.
In practical applications, according to specific circumstances, other aspects may also need to be tested. In short, the purpose of the test is to ensure that the ultra-high voltage transformer mutual inductor vacuum oil filling platform can achieve the expected effect during the process of injecting the oil, and to ensure the performance and safety of the mutual inductor.
Hot Tags :