Product Introduction:
The helium detection equipment for pressure sensors is highly precise and automated, using helium to detect minute leaks, ensuring that the product sealing meets standards, and is widely used in automobile manufacturing and other industries.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
90 DaysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0025Product Features:
This set of helium leak detection system is tailor-made for the airtightness detection of the sensor core, with fast detection speed and high accuracy, and a leakage rate of 1.0E-8 Pa.m3/sec, and two detection workstations.
Product Parameters:
Tracer Gas |
Helium |
Applicable Workpiece |
Pressure Sensor Core |
Leak Detection Helium Pressure |
50 KPa (Adjustable downwards) |
Alarm Leak Rate |
1.0E-8 Pa.m³/sec |
Number of Leak Detection Stations |
2 |
Capacity per Station |
2 workpieces per installation |
Production Cycle Time |
10 s/piece, including loading and unloading time |
Installation Requirements:
Installation must be carried out by trained professional installers only.
The installation of the equipment at the site requires the following conditions:
(1) Power Supply for the Main Unit
Electrical parameters: Three-phase 5-wire 380VAC, power 5KW.
Switch: 1 air switch, with a height from the ground ≥1.5M, and a distance from the placement position of the main unit ≤2M.
(2) Gas Source
① Helium: ≥1 bottle of bottled helium (40 liters, 12MPa), with 1 0.2MPa pressure reducing valve;
② High-purity Nitrogen: Bottled high-purity nitrogen (≥99.999%), with 1 0.2MPa pressure reducing valve;
③ Compressed Air: Clean compressed air with a pressure ≥0.55MPa, equipped with a 1/2″ ball valve;
The distance between the gas source interfaces and the placement position of the machine should be ≤1M.
(3) Others
① Prepare an outdoor exhaust pipe with a diameter ≥3/4″, and the distance between the interface and the placement position of the machine should be ≤1M.
Hot Tags :