Product Introduction:
According to the basic principle of helium leak detection, helium is used as a tracer gas to charge helium into the workpiece, and then the accuracy of workpiece leakage can be quickly and accurately determined by helium leak detector.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
90 DaysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0089Installation Requirements:
The installation can only be conducted by trained professional installers.
The installation of the equipment at the site requires the following conditions:
(1) Main Power Supply
Electrical parameters: three-phase five-wire 380VAC, power 15KW.
Switches: 8 air switches, with a height above ground of ≥1.5M and a distance to the main equipment placement position of ≤2M.
(2) Gas Supply
① Helium: ≥1 bottle of bottled helium (40 liters 12MPa) with a 0.1MPa pressure reducing valve;
② High-purity nitrogen: bottled high-purity nitrogen (≥99.999%) with a 0.2MPa pressure reducing valve;
③ Compressed air: clean compressed air with a pressure of 0.55-0.7MPa;
The distance between the gas supply interfaces and the placement position of the machine should be ≤1M.
(3) Others
① Prepare an outdoor exhaust pipe with a diameter of ≥3/4″, and the distance between the interface and the placement position of the machine should be ≤1M.
Product Parameters:
Workpiece |
Heating tank |
Vacuum chamber |
1 chamber (each chamber can test 2 work pieces) |
Chamber size |
L700mm*W300mm*H600mm |
Maximum workpiece size |
Ø240*400 |
Equipment accuracy |
5x10-6mbar.L/s |
Helium Recovery |
Recovery Rate ≥95% |
Hot Tags :