Product Introduction:
According to the basic principle of helium leak detection, helium is used as a tracer gas to fill the workpiece in a vacuum chamber. Then, a helium leak detector is used to detect the helium signal in the vacuum chamber, thereby quickly and accurately determining the overall leakage situation of the workpiece with high precision.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
90 DaysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0094Operation Procedure:
The operator needs to push the workpiece into the vacuum chamber, connect the quick-connect coupling inside the vacuum chamber to the workpiece interface, press the close chamber button, and the system can automatically complete the entire process of gross leak detection, evacuation, micro-leak detection, helium recovery, and so on.
Product Features:
1.Background Cleaning Technology:
The system features a unique background cleaning technology that ensures thorough cleaning of the vacuum chamber and associated piping before each inspection, stabilizing the helium background signal.
2.Calibration Technology:
The system supports automatic calibration, accurately determining the overall leak rate of the workpiece, and achieving online calibration of system accuracy through a standard leak hole.
3.User-Friendly Operation:
The system integrates process automation and electrical automatic control, allowing for automatic control of the workpiece inspection process via PLC and a touchscreen interface, reducing the operator's workload.
4.Quality Assurance:
The automated inspection process reduces human factor interference, ensuring consistency, stability, and repeatability in operations. The quality is certified by the National Institute of Metrology, China.
Product Parameters:
Leak Test Stations |
2 stations, capable of testing 1 workpiece each |
Vacuum Chambers |
2 chambers, capable of accommodating 1 workpiece each |
Chamber Dimensions |
L*W*H=1000mm*600mm*250mm (Based on customer-provided dimensions) |
Workpiece Clamps |
4 sets, 2 sets for each workpiece |
Large Leak Detection Gas |
Nitrogen |
Large Leak Test Pressure |
25bar (adjustable downward) |
Micro-leak Detection Gas |
100% Helium |
Micro-leak Test Pressure |
25bar (adjustable downward) |
Alarm Leak Rate |
For refrigerant R134a, 3g/year, equivalent to 1.5*10-5 Mbar.L/s |
Cycle Time |
30 seconds per workpiece (120 workpieces per hour) |
Helium Recovery |
Automatic recovery system, helium recovery rate ≥98% |
Hot Tags :